Furuno FR-2125V User Manual

Page 135

Advertising
background image

SP - 2

(4) Range Scales and Ring Intervals

0.125, 0.25, 0.5, 0.75, 1, 1.5, 2, 3, 4, 6, 8, 12, 16, 24, 32, 48, 96

0.025, 0.05, 0.1, 0.25, 0.2, 0.25, 0.5, 0.5, 1, 1, 2, 2, 4, 8, 8, 12, 12

(5) Range Accuracy

1% of range in use or 15 m whichever is the greater

(6) Range Discrimination

25 m

(7) Bearing

Accuracy

±1°

(8) Bearing

Discrimination 2.5°

(9) Presentation modes

Head-up, Head-up TB, North-up, Course-up, True Motion North-up

(Heading signal required except for HU)

(10) Variable Range Markers Two Variable Range Markers, switched
(11) Offcenter

Sweep origin can be offcentered by 50% of range in use in any direction

(Not available for maximum range)

(12) Guard Zone

Anywhere above 0.7 SM

(13) Electronic Plotting Aids (EPA)

10 Targets Providing Range, Bearing, Course, Speed, CPA and TCPA

Note: EPA disabled when ARPA function is used.

(14) Parallel Index Lines

2, 3 and 6 lines (selectable on menu)


4. INTERFACE
(1) Gyrocompass

Built-in interface accepts synchronized signal (20-50 V, 50-400 Hz)

(2) Speed Log

Built-in interface accepts contact closure or DC signal at 200, 400 or 500

pulses/sm.

(3) External Radar (option)

Built-in interswitch for 2 channels provided


5. POWER SUPPLY
(1) DC Source

24-32 VDC: 10.8-8.2 A, 260VA

(2) AC Source

100-115/220-230 VAC: 4.1 A, 1 phase, 50-60 Hz, 410 VA


6. ENVIRONMENTAL CONDITION
(1) Ambient Temperature (Complies with IEC60945)

Display Unit:

-15°C to +40°C

Antenna Unit:

-25°C to +70°C

(2) Relative Humidity

95% at 40°C

(3) Water proofing

Display Unit (Panel): IPX2

Antenna Unit: IPX6

(4) Vibration

±1 mm ±10%, 2(5) to 13.2 Hz,

Maximum acceleration 7 m/s

2

, 13.2 to 100 Hz

Advertising