5.4

Start-up Procedure

The ARPA requires own ship’s speed input and heading data. The speed can be entered
automatically from a speed log (SDME, Speed and Distance Measuring Equipment), navaid,
or by referencing to a target-based speed (based on three max. stationary objects). Manual
input is also possible.

5.4.1

Automatic speed input

For speed log input:

1. Press the [RADAR MENU] key and the [0] key to show the FUNCTIONS 2 menu.

[FUNCTIONS (1)]
1 TARGET TRAILS
2 GUARD ALARM (1 or 2)
3 ORIGIN MARK (1 to 10)
4 INDEX LINES
5 ZOOM
6 PULSE WIDTH
7 INT REJECT
8 ARPA
9 VIDEO PLOT
0 [FUNCTIONS (2)]

[RADAR MENU] key

[0] key

[FUNCTIONS (2)]
1 [FUNCTIONS 1]
2 BKGD COLOR

BLK(GRN CHAR)/

BLK(RED

CHAR)/

BLU

(ECHO

AREA)

BLU/

BRT BLU

3 ECHO STRETCH

OFF/1/2/3

4 ECHO AVERAGE

OFF/1/2/3

5 ECHO COLOR

YEL/GRN/COLOR

6 SHIP SPEED

LOG/NAV/MAN

MAN = 00.0KT

(STW/SOG)

7 SET, DRIFT

OFF/MAN

SET = 000.0

°

DRIFT = 00.0KT

8 INDEX LINES

NO. 2 VRM/MAN
MAN = 00.00NM

9 ]BRILLIANCE (1)]
0 [FUNCTIONS (3)]

Figure 5-3 Keying sequence for entering ship’s speed

2. Press the [6] key to select SHIP SPEED.

3. Press the [6] key to select LOG (or NAV) option.