Frymaster FOOTPRINT PRO SERIES 35 User Manual

Page 15

Advertising
background image

2-5

4. Test the fryer electrical system:

a. Plug the fryer electrical cord(s) into a grounded electrical receptacle.

b. Place the power switch in the ON position.

• For fryers equipped with thermostat controls, verify that the power and heat lights are lit.

• For fryers having computer or digital displays, verify that the display indicates

c. Place the fryer power switch in the OFF position. Verify that the power and heat lights are

out, or that the display is blank.


5. Refer to the data plate on the inside of the fryer door to verify that the fryer burner is configured

for the proper type of gas before connecting the gas line quick-disconnect device or piping from
the gas supply line.


6. Verify the minimum and maximum gas supply pressures for the type of gas to be used in

accordance with the accompanying tables:

Model

Gas Type

G20

G25

G31

G20

G25

G31

Pressure

(mbar)

1

20

20-25

37-50

20

20-25

37-50

Number of

Orifices

9

9

9

18

18

18

Manifold

Pressure

9

13,5

22,5

7,5

10

20,6

1

(mbar) = 10,2 mm CE

Orifice

Size

2,50

3,06

1,51

3,10

3,58

1,80

1,40

Table 1: CE Standard for Incoming Gas Pressures

Model 35

Model 45

1,40

0,86

Air Flow

(m

3

/H)

1,70

1,70

1,05

Table 2: Non-CE Standard

for Incoming Gas Pressures

Gas

Minimum

Maximum

Natural

6" W.C.

1.49 kPa

14.93 mbar

14" W.C.

3.48 kPa

34.84 mbar

LP

11" W.C.
2.74 kPa

27.37 mbar

14" W.C.

3.48 kPa

34.84 mbar


7. For fryers equipped with a built-in filter system and/or basket lifts, plug the electrical cord(s) into

a power receptacle behind the fryer.