Frymaster FOOTPRINT PRO SERIES 35 User Manual

Page 32

Advertising
background image

4-7

DANGER

Do not drain more than one frypot at a time into the built-in filtration unit to avoid
overflow and spillage of hot oil/shortening.

DANGER

NEVER attempt to clear a clogged drain valve from the front of the valve! Hot oil or
shortening will rush out creating the potential for severe burns.

DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage
to the ball inside will result in leaks and will void the Frymaster warranty.







2. If present, install the optional Power

Shower. NOTE: Verify that the Power
Shower O-ring and gasket are present
and in good condition and that the clean-
out screws are installed at each corner. If
the frypot is front flush, there are no
accessories to install.

Install the Power

Shower in the frypot

to be filtered.

Snap the Power Shower into position.

DANGER

DO NOT operate the filter without the Power Shower in place. Hot oil will spray out of
the fryer and cause injury.

3. After the cooking oil has drained from

the frypot, rotate the Oil Return handle
left to the RETURN position to start the
pump and begin the filtering process.
There may be a slight delay before the
pump activates. On fryers equipped with
an optional rear- disposal system (See
Section 4.6), rotating the handle to the
right will discharge the oil.

Rotate the handle to the left to return oil to the frypot.
Rotate to the right on fryers with optional rear-
discharge to dispose of the oil.

Advertising
This manual is related to the following products: