5 blockage between filter pan and flex-hose valve – Frymaster Portable Filters MF90 Series User Manual

Page 25

Advertising
background image

6-5

Blockage Between Filter Pan and Flex-Hose Valve

Disconnect oil line from

filter pan to pump at the

pump end.

Pump is clear; plug is

in the bottom of the

filter pan or in the line

from the pan to pump.

Disconnect line at filter pan.

Can you blow air through line

from pump to pan?

Turn pump ON and allow it to

operate for a few seconds to ensure

it does not run backwards.

Put your finger over the

pump inlet. Is suction

present?

Remedy problem and continue

filtration process.

Blockage is in pump or in

the discharge line.

Possible blockage

between filter pan

bottom and flex-hose

disconnect.

Yes

No

Yes

Line is blocked. Remove

line, soften and clear
solidified shortening.

No

Reconnect line and

operate pump. If still

no oil flow, blockage

is in bottom of pan.