5. INITIAL

SETTINGS

Checking Operation

1. Turn on the GP-80.
2. Confirm that "OK" and "BEACON RCVR INSTALLED" are display on the self-test

display.

Confirm that "BEACON RCVR
INSTALLED" is displayed when
DGPS function is provided.

BEACON RCVR INSTALLED
DATA #3: LOG PULSE OUTPUT

PROGRAM MEMORY

=OK

SRAM

=OK
=OK

Internal Battery

Self-test display at equipment start up


3. At the GP-80, press [MENU ESC], [8] and [1]. Confirm that "BEACON OK" is displayed.

DGPS Setup

The default setting is "manual".

Automatic DGPS setup

The GR-800 can automatically select optimum reference station by feeding it position data.
If it takes more than 5 minutes to fix DGPS position at the automatic mode, switch to
manual mode. Use at manual mode when a external beacon receiver has no automatic
function of station selection.

1. Press [MENU ESC], [9] and [7] to display the DGPS SETUP menu.

These items appear when
"MAIN" is selected.

DGPS SETUP

Freq.

288.0kHz

ENT: Enter

MENU: Escape

Baud Rate

200 bps

DGPS MODE

Ref. Station

Auto

Man(ID= )

___

:Select

On Off

DGPS SETUP menu


2. Press

!

or

"

to select DGPS MODE and press

#

to select On.

3. Press

!

or

"

to select Ref. Station.

4. Press

#

to select Auto.

Advertising