3. ANTENNA UNIT

4

How to attach the N-P-8DFB connector

Outer Sheath

Armor

Inner Sheath Shield

Remove outer sheath and armor by the dimensions
shown left.
Expose inner sheath and shield by the dimensions
shown left.

Cut off insulator and core by 10mm.

Twist shield end.

Clip on clamp nut, gasket and clamp as shown left.

Fold back shield over clamp and trim.

Cut aluminum foil at four places, 90

°

from one

another.

Fold back aluminum foil onto shield and trim.

Expose the insulator by 1mm.

Expose the core by 5mm.

Slip the pin onto the conductor. Solder them together
through the hole on the pin.

Insert the pin into the shell. Screw the clamp nut into
the shell.
(Tighten by turning the clamp nut. Do not tighten by
turning the shell.)

Cover with heat-shrink tubing and heat.

30

10

Clamp
Nut

Gasket
(reddish
brown)

Clamp

Aluminum Foil

Trim shield here.

Trim aluminum
tape foil here.

Insulator

1

5

Clamp Nut

Pin

Shell

Solder through
the hole.

50

30