General data – Furuno GP-80 User Manual

Page 15

Advertising
background image

5. INITIAL SETTINGS

12

AGFPA: Autopilot information from FURUNO autopilot equipments

Port Input

Output

DATA1
DATA2

NMEA 0183
Ver. 1.5 /2.0
AGFPA , DBT, DPT,
MTW, TLL

IEC 61162-1/NMEA 0183 Ver.1.5/
Ver.2.0
AAM, APA, APB, BOD, BWC, BWR,
BWW, GGA, GLL, GNS, RMB, RMC,
VTG, WCV, WNC, WNR, WPL, XTE,
ZDA, ZLZ, ZTG, Rnn, RTE, DTM

LOG PULSE

DATA3

External MOB

Same as the data output form “DATA1”

General data

DATA4

DGPS or general data
(Selected by menu)

IEC 61162-1/NMEA 0183 Ver.1.5/
Ver.2.0
AAM, APA, APB, BOD, BWC, BWR,
BWW, GGA, GLL, GNS, RMB, RMC,
VTG, WCV, WNC, WNR, WPL, XTE,
ZDA, ZLZ, ZTG, Rnn, RTE, DTM

General data

1) Input of buoy information

Floppy disk stored buoy information is supplied from PC connected at DATA4 port.

2) Input of waypoint data

Connect YEOMAN equipment to DATA4 port.

3) Input and output of waypoint / route data

Rate of operation

The TX rate of operation is the percentage of data output in one second, and it appears on
the screen. If short intervals are assigned to many sentences, the rate of operation
increases as illustrated below

TX

TX

TX

A rate of operation exceeding 100% is impractical. For better performance, the rate of
operation should be less than 90%.

When the external equipment cannot display correct data input from the GP-80, the rate of
operation should be lowered.

For example, set a rate of operation less than 60% for the Temperature Indicator TI-20.

Advertising