13 data 1 output setting – Furuno GP-80 User Manual

Page 16

Advertising
background image

5. INITIAL SETTINGS

13

DATA 1 output setting

1) Press [MENU] [9] and [3]. The DATA 1, 3 OUTPUT SETUP menu appears.

Talker ID

GP

LC

DE

Output Data (00-90 sec)84%

1. AAM:00

APA:00

APB:01 BOD:00

2. BWC:00 BWW:00 GGA:01 GLL:00

3. RMB:01

RMC:01 VTG:01 WCV:00

4. WINC:00 WPL:00

XTE:00

ZDA:01

5. GNS:00

ZTG:000 Rnn:00

RTE:00

DATA3. Log Pulse

400ppm

DATA 1, 3 OUTPUT SETUP

MENU : Escape

ENT : Enter

200ppm

Settings shown here are default settings.

This line appears only when LOG is
selected by internal jumper wires.

Data Fmt.

V1.5

IEC

V2.0

Figure 5-1 DATA 1, 3 OUTPUT SETUP menu


2) Press

!

or

"

to select Data Fmt.

3) Press

#

or

$

to select V1.5, V2.0 or IEC.

4) Press the [ENT] key. Talker ID appears in reverse video.
5) Press

#

or

$

to select GP, LC or DE.

6) Press the [ENT] key.
7) Enter Tx interval for each output data sentence in line 1. Tx interval is available in 00,

01, 02, 03, 04, 05, 06, 10, 15, 20, 30, 60, and 90 sec.

8) Press the [ENT] key.
9) Enter Tx interval for each output data sentence in lines 2 through 5. Press the [ENT] key

after setting each line.


In great circle calculation, BWC and WNC are output but BWR and WNR are not. In rhumb
line navigation, BWR and WNR are output but BWC and WNC are not.
The total data output are shown by percentage on the third line.
For best results the total output should be less than 90%; lengthen the Tx interval of less
important data to make the total output less than 90%.