18 interface documentation – Furuno GP-80 User Manual

Page 21

Advertising
background image

5. INITIAL SETTINGS

18

Interface Documentation

"DATA1" Port
! IEC 61162-1/NMEA 0183 Ver. 1.5 Output

Output Schematic Diagram (Talker)

1

2

6

6

7

8

DATA 1

J5

TD-A

TD-B

FL14

FL13

MJ-A6SRMD

20P8147

U35
SN75ALS172

Output Drive Capability

Max. 10mA

IEC 61162-1 output subject to the standard of IEC 61162-1 First edition 1995-11.

Output Sentence is described on page 8 and 9. Each sentence is output at the interval
entered.


! NMEA 0183 Input

Input Schematic Diagram (Listener)

1

J5

2

3

4

5

6

RD-H

RD-C

1

3

4

5

FL11

DATA 1

20P8147

MJ-A6SRMD

R77
470

FL12

CR13
1SS226

PC-400
U17

+5V

R64
2.2K

Load Requirements

Isolation: opto

coupler

Input Impedance: 470

Max. Voltage:

±

15V

Threshold:

3mA (In case of FURUNO device talker connection)

Input Sentence is described on page 11.

Advertising