5. INITIAL SETTINGS

20

"DATA3" Port

The output signal of this port is changed by jumper JP4 and JP5 between data out (IEC
61162-1/NMEA 0183 Ver.

1.5/Ver. 2.0) and log pulse.

In case of data out, the same data of DATA1 port (#1 & #2) is output.

Output Schematic Diagram (Talker)

20P8147

MJ-A6SRMD

14

13

12

1

3

2

4

DATA3

1

J6

2

3

4

5

6

FL5

FL6

JP4

TD-A

TD-B

U35
SN75ALS172

Output Drive Capability

Max. 10mA


"DATA4" Port
IN/OUT signal is selected by the menu among the output of IEC 61162-1, NMEA 0183 Ver.
1.5/Ver. 2.0, PC output/input and DGPS signal. Also, to select DGPS signal, jumper JP3 is
required to connect "external DGPS receiver."
RS-232C or RS-422 level can be selected by the menu.
In case of output of IEC 61162-1, NMEA 0183 Ver. 1.5/Ver. 2.0,

Data format can be selected by the menu between IEC 61162-1 and NMEA 0183 Ver.
1.5/Ver. 2.0.

Output sentence is described on page 8 and 9.

Each sentence is output at the interval entered.