5. INITIAL SETTINGS

15

Setting DATA 4 to Data Output

1) Press [MENU] [9] and [5]. The DATA 4 I/O SETUP menu appears.

DATA 4 I/O SETUP 1/2

To Next Page

ENT : Enter

MENU : Escape

Appears only when external
DGPS receiver is used.

DATA 4. Level

RS232C

RS422

Data

Out

Com. DGPS

: Select

Figure 5-3 DATA 4 I/O SETUP menu


2) Press

!

or

"

to select Level.

3) Press

#

or

$

to select level of external equipment; RS232C or RS422.

4) Press the [ENT] key.
5) Press

#

or

$

to select Out.

6) Press

"

to select to Next Page. The DATA 4 I/O SETUP menu appears.

To Previous Page

Talker ID

GP

LC

DE

Output Data (00-90 sec) 84%

DATA 4 I/O SETUP <Out> 2/2

MENU : Escape

ENT : Enter

Data Fmt.

V1.5

V2.0

IEC

1. AAM:00 APA:00

APB:01

BOD:00

2. BWC:00 BWW:00 GGA:01 GLL:00

3. RMB:01 RMC:01 VTG:01

WCV:00

4. WNC:00 WPL:00

XTE:00

ZDA:01

5. GNS:00 ZTG:00

Rnn:00

RTE:00

Figure 5-4 DATA 4 I/O SETUP menu


7) Follow "DATA 1 output setting" from step 2.