Setting method 1: DIP switch settings and gyrocompass specifications

1) Gyrocompass type 2) Frequency

Gyrocompass
type

SW

1-4

SW

1-5

SW

1-6

JP1

Frequency

SW

1-7

SW

1-8

Remarks

AC
synchronous

OFF

OFF OFF

#1, #2,
#3

50/60 Hz

OFF

OFF

AC synchronous
pulsating current

DC
synchronous

OFF

OFF OFF

#2, #3,
#4

400 Hz

ON

OFF

AC synchronous
pulsating current

DC step

ON

OFF

OFF

#4, #5,
#6

500 Hz

OFF

ON

AC synchronous
pulsating current

Full-wave
pulsating current

OFF

ON OFF

#4, #5,
#6

DC ON

ON

DC synchronous
DC step

Half-wave
pulsating current

ON ON OFF

#4, #5,
#6

3) Rotor Voltage (between R1 & R2) 4) Stator Voltage (between S1 & S2)

Rotor Voltage

SW

2-1

JP3

Stator
Voltage

SW

2-2

SW

2-3

JP2

20 to 45 VAC

ON

#2

20 to 45 VAC, or
20 to 60 VDC

ON OFF #2

30 to 70 VAC

OFF

#2

30 to 70 VAC, or
40 to 100 VDC

OFF

OFF #2

40 to 90 VAC

ON

#1

40 to 90 VAC

ON

OFF

#1

60 to 135 VAC

OFF

#1

60 to 135 VAC

OFF

OFF

#1

5) Ratio 6) Supply Voltage

Ratio

SW

1-1

SW

1-2

SW

1-3

Stator
Voltage

JP4 JP5

360X

OFF

OFF

OFF

20 to 45 VAC, or 20 to 60 VDC

#2

#2

180X

ON

OFF

OFF

30 to 70 VAC, or 40 to 100 VDC

#1

#1

90X OFF

ON OFF

36X ON

ON

OFF

7) AD-10 format data 8) NMEA-0183

Tx interval Tx interval and Output sentence

Select data transmitting interval for ports 1 to 6 with jumper
wires JP6 and JP7: #25 for 25 ms, #200 for 200 ms.

Tx
interval

SW
2-5

SW
2-6

Output
sentence

Note: The Tx interval is available in 25 msec or 200 msec.

1 s

OFF

OFF

HDT+VHW

Use 25 msec for radar.

200 ms

ON

OFF

HDT

100 ms

OFF

ON

HDT

25 ms

ON

ON

HDT

9) NMEA-0183

Version no.

10) NMEA-0183

Baud rate

11) Power fail

detection

12) Stator signal

breaking detection

Version no.

SW3-1

Baud rate

SW3-2

Talker

SW3-3

Detection

SW2-7

1.5 OFF

4860bps

OFF

Disable

OFF

Execute

OFF

2.0 ON

38400bps

ON Enable

ON

No execute

ON

(Use OFF for radar.)

SW2-4: factory use only
SW3-4: not used