4. INSTALLING OPTIONAL EQUIPMENT

4-19

Cable fabrication

RW-9600

6

14 5 9

approx. 450

5

20

Armor

Units: mm

Shield

Vinyl sheath

Pull out inner cables from here.

Shield

Coaxial cable

Crimp on lug for M8

DPYC-6 and TTYC-4

20

5

6

DPYC-6: approx. 130
TTYCY-4: approx. 150

Conductor
S = 0.75 mm

= 1.11 mm

2

TTYCY-4 (Four twisted pairs)

Armor

Sheath

= 17.7 mm

Sheath

Conductor
S = 6 mm

I

= 3.12 mm

2

DPYCY-6

Armor

Sheath

I

= 13.9 mm

Armor

Vinyl sheath

Taper for unused wires.

I

I

RG-12/UY

20

60

14

9

5

Vinyl sheath

Armor

Inner conductor

Outer conductor

Advertising