4. INSTALLING OPTIONAL EQUIPMENT

4-15

4.4 Performance Monitor PM-31

This kit is installed in the antenna unit of the FAR-2107/2807 series X-band radar to monitor
radar performance.

Name:

Performance

monitor

Type:

PM-31

Code

no.: 008-080-438

Name

Type

Code

number

Qty

Ԙ SCANNER COVER ASSY.

PM-31

008-539-430

1

ԙ GREASE

GASKET GREASE #2
50G

000-149-704 1

Ԛ SM-XH CONNECTOR

ASSY.

03-2108

㧔6P-6P)

008-534-840 1

ԛ LIFTING FIXTURE

03-001-3264

300-132-640

1

Ԝ GASKET 03-001-3263

300-132-631

1

Procedure

To hoist the scanner cover assy. to the radar mast, by using rope, attach the lifting fixture

ԛ to

the scanner cover assy.

Ԙ.

1. Remove the bolt and chain at the bottom of the stern-side cover, and then remove the
cover.
2. Coat the bolt hole on the scanner cover assy.

Ԙ with silicone sealant (Adhesive 1211)

and secure the chain with the bolt.
3. Remove the cover at the bow side also.
4. Insert the XH connector of the SM-XH connector

Ԛ assy. to J911 on TB board 03P9349

and the SM connector of the SM-XH connector assy. to the relay plate.
5. Coat the gasket

Ԝ with the gasket grease #2 50G ԙ and attach it to the scanner cover

assy.

Ԙ.

6. Connect the cable assembly coming from the scanner cover assy.

Ԙ to the SM connector

attached at step 4 above.
7. Attach the scanner cover assy. to the stern side of the antenna unit.
8. Reattach the bow-side cover.