16 installation, For qualified installers only), Installation warning – remote synchronization – FireplaceXtrordinair Revolution 36CF User Manual

Page 16: Battery installation

Advertising
background image

16

Installation

(for qualified installers only)

© Travis Industries

4090102

100-01212_000

Steps for Installing the Battery Box and Learn Switch

1. Remove the control cover and attach the 12’ long battery box wire to the quick connects on the

receiver module (see Figure 9 below). Route the battery box wire through the opening below
the cover. At this time make sure the continuous pilot switch is set to “OFF” and the remote
switch is set to “REMOTE” on the receiver module – item “a”). You may also wish to verify all
the wire leads are fully attached.

POWER

MOTOR

Learn

Continuous

Pilot

Off/On

Remote/Off

ADJ

S

I

Motor Wires (for flame height adjustment)
Red, Yellow, White, and Blue wires

White

Green

Orange

White

Main Burner Control Wires

Pilot Flame Control Wires

Sensor ("S")
Wire (White)

Brown Switch

Wires (not

used)

Battery Box

(external junction box)

Gas Control Valve

Receiver

Module

Pilot Assembly

Make sure continuous pilot

is set to "OFF" and remote

is set to "REMOTE".

a

Igniter ("I") Wire

(Orange - with

fiberglass

insulation)

AC Adapter

(wire orientation does not matter)

COMM.

Black

Ground

Battery Wires
Red and White Wires

Learn Wires
Two White Wires

Power Input

Auxiliary Power

(Not Used)

Accent Light Wires
Orange and White Wires

Make sure continuous pilot

is set to "OFF" and remote

is set to "REMOTE".

120V Extension Module

Figure 9

2. Determine a location for the single-gang junction box that contains the battery pack and learn

switch. It must be located within 12’ of the fireplace. Mount the junction box.

3. Insert the battery box wires through the junction box, leaving approximately 8” of slack so the

battery pack may be removed and the batteries replaced. Use a staple or other means to
secure the wiring to the framing – this prevents the wires from slipping out of the junction box in
the event the wires become disconnected from the battery pack (see Figure 8). NOTE: The
wiring is low-voltage (6V) and does not require a strain relief. Connect the learn switch and
battery pack wires (see Figure 9).

4. Place batteries inside the battery pack and place it inside the junction box. Attach the remote

holder to the junction box with the included screws.

INSTALLATION WARNING – Remote Synchronization

At this time we highly recommend you verify the remote and fireplace are synchronized. This
process requires access to the learn switch. See the instructions on page 17 for details.

Battery Installation

This fireplace uses four AA batteries for operation during power outages. Place the batteries into
the battery box. In addition, two AAA batteries are required for the transmitter.