Finalizing the Installation

(for qualified installers only)

37

© Travis Industries

4090102

100-01212_000

7. Check the air shutter following the directions below.

Air Shutter Adjustment

Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should
be yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame.

Correct

Flames should be blue at the
base, yellow-orange on the top.

If the flames are too tall or sooty on the
ends, open the air shutter.

Not Enough Air

If the flames are all blue and
short, close the air shutter.

Too Much Air

How to Adjust the Air Shutter

The three air shutters (two sides and center) are located to the back of the burner (under the exhaust)
and are accessed by removing the glass frame (and the rear log, if needed – see the picture below).
The air shutter levers may be adjusted – a screwdriver of other tool may be used to “tap” the lever to
the desired position. Slide the shutter towards the back (exhaust) to close, to the front (towards the logs)
to open. After adjusting the air shutter replace the glass and verify flame quality.

8. Adjust the flame height to its highest position - the flames should not contact the top of the

firebox. Check the flame on lowest position. The flames should burn off each burner hole. If
the heater does not work correctly, contact your Travis dealer for a remedy.

9. Give this manual to the home owner for future reference and fully explain operation of this

heater. For comprehensive operating and maintenance instructions, refer to the Owner's
Manual.