32 installation, Side view, For qualified installers only) – FireplaceXtrordinair Revolution 36CF User Manual

Page 32: Hearth requirements – recessed hearth

Advertising
background image

32

Installation

(for qualified installers only)

© Travis Industries

4090102

100-01212_000

Hearth Requirements – Recessed Hearth

A hearth is not required if the fireplace is raised 6” above the

flooring surface. NOTE: Make sure to accommodate the flooring

surface - this distance must be measured from the top of carpeting

or other flooring material.

WARNING:

We recommend a hearth to protect the flooring

surface from discoloration or other negative

impact from the heater, especially if it is near the

minimum raised height.

Min. 6”

Side View

Fireplace

NOTE: When building a raised fireplace, consider the facing

material below the fireplace. If using tile, you may wish to

make the platform a suitable height for un-cut tile. For

example, if using 12” tile, make the platform 11” tall (10-1/2”

section of framing + 1/2” plywood).

1”

Cement Board

Plywood (OSB, etc.)

Framing

Sub-Floor

Minimum 6” to top of

flooring surface

(carpet, etc.)

Carpet

Figure 21

Advertising