Finalizing the Installation

(for qualified installers only)

47

© Travis Industries

4090102

100-01212_000

Power Heat Duct Installation

The optional power heat duct may be
used with this fireplace. Refer to the
part numbers below if you wish to insta
this accessory. Instructions are includ
with the power heat duct.

Power Heat Duct (98500769)

1080/36 ST-Pier CF Power Heat
Duct Wiring Kit (94400995) -
required for thermodisk
controlled on/off operation

NOTE: The power heat duct must be

attached at the time of fireplac
installation.

Electrical
Source

Starter Ring

Use 10” x 3-1/4”
wall stack (duct)
when passing
through tight
areas.

6" Duct

Duct Adapter
(6” Round to 10” x 3-1/4”)

Floor
Boot

Grill

Rheostat
(with cover plate)

Junction Box

Wall Adapter
(for use on
2 x 4 walls)

Heat Duct
Electrical
Wiring

Blower
Box

Maximum Duct

Length = 20'

Andiron Installation

This fireplace includes four andiron brackets
that allow for use of the optional andirons.
Follow the directions below if installing
andirons. NOTE: The firebacks should be
installed prior to installing the andirons.

1

The andiron clip attaches to the front of the
burner (there are two on each side for a total
of four). Remove the screw and attach the
clip. NOTE: the firebacks are not pictured
in the pictures.

2

Secure the andiron to the clip with the bolts
included with the andirons. We recommend
you pre-thread the andirons to ease
installation.