Installation

(for qualified installers only)

11

© Travis Industries

4090102

100-01212_000

Minimum Framing 36 CF ST (See Through)

62-1/2"

Minimum 78” Fireplace

Enclosure Height

NOTE:

We recommend you install the

framing after placing the fireplace in

position.

As an alternative, you may omit the

framing above one side and back of the

fireplace until the fireplace is in position

(shown in gray).

56-1/2"

22-1/2"

Right

Left

Front

Back

42-1/4"

If venting to the rear using a 45° elbow directly

off the fireplace, the vent will be 42-1/4" above

the base of the fireplace.

Vent Clearances:

8-5/8" Diameter vent requires 3-1/2" clearance

to the sides. You may need to notch the

framing to accommodate this clearance.

15-5/8"

Figure 5