Finalizing the Installation

(for qualified installers only)

© Travis Industries

4090102

100-01212_000

11 The gas control valve has a propane conversion shaft that alters the outlet pressure. Remove

the rubber cap over the propane conversion shaft and twist the small knob so the line points to
“LP” (see Figure 27).

Pilot Adj.

Inlet

Outlet

NATURAL TO PROPANE
CONVERSION SHAFT
(UNDER RUBBER CAP)

LP

NAT

NAT

LP

Main

Pilot

Side View

NG

(Natural Gas)

LP

(Propane)

Conversion Shaft

(Note how it is in a lower

position when switched to LP)

Figure 27

12 Remove the NG rate screw and replace it with the LP rate screw included in the owner’s pack

(see Figure 28). Take care to not damage the rubber o-ring on the rate screw when installing.

Pilot Adj.

Inlet

Outlet

RATE SCREW (BRASS)

LP

NAT

NA T

L

P

Main

Pilot

LP

(Propane)

NG

(Natural Gas)

Rate Screws

Figure 28

13 Return the fireplace to the correct configuration (replace firebox and valve cover components).

14 The fireplace receiver module will need to be configured for LP. This is done by pressing and

holding the “Learn” switch FOR 20 SECONDS (see “Battery Pack / Learn Switch Installation” on
page 15). The receiver will give off a short beep (less than 1 second) when configured for LP.
The receiver will give off a long beep (3 seconds) when configured for NG. By pressing the
switch for 20 seconds, you toggle between the two settings.

15 Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly

leak-test all gas connections and the gas control valve (see Gas Line Requirements on page 18
for details). Check the pilot and adjust if necessary.

Advertising