Connect Mode

This parameter defines how the VMSE makes a connection and how it reacts to
incoming connections over the network.

Function

7

6

5

4

3

2

1

0

Connection Acceptance
-never accept incoming

0

0

0

-accept incoming with active DTR only

0

1

0

-accept unconditional (if not busy)

1

1

0

Response on Serial to Connect
-nothing (quiet)

0

-character response: (C=conn., D=disc.,

N=not available/unreachable)

1

Active Connection Startup
-no active connection startup

0

0

0

0

-start connection with any character on

the serial line

0

0

0

1

-start connection with active-going

DTR line

0

0

1

0

-start connection with CR (0x0d) only

0

0

1

1

-manual connection startup

(‘C’ + address)

0

1

0

0

Datagram Mode

1

1

0

0

Modem Emulation Mode

0

1

1

0

Figure 4-4. Connect Mode Options

Please refer to Appendix B for information on converting values to hexadecimal
format.

Automatic Connection Address

Using either of the serial ports, an automatic TCP connection to a network node can
be configured by setting the remote IP address and the TCP port number parameters.

If automatic connection is selected, all parameters must be supplied in full.

If manual connection startup is configured (with “C” + address/port), only the part
not supplied in the command string is used. In manual mode, the last byte of the
address must be supplied.