Operation/diagnostics, For compass units with the a-series controller – Golden Technologies GP601 SS User Manual
Page 26
Compass Onwer’s Manual – Models GP600 SS, GP600 CC, GP601SS, GP601 CC Revised 060208
26
OPERATION/DIAGNOSTICS
For Compass Units with the A-SERIES Controller
Flash codes indicate the nature of an abnormal condition directly from the A – Series
Information Gauge. Without the use of any servicing tools, the condition can be
simply diagnosed.
Flash
Code
Description
Recommended Action
1
User Fault
Possible stall timeout or user error. Release
the joystick to neutral and try again.
2
Battery Fault
Check the batteries and cabling. Try charging
the batteries. Batteries may require replacing.
3
Right Motor Fault
Check the right motor, connections and
cabling.
4
Left motor fault
Check the left motor, connections and
cabling.
5
Right park brake fault
Check the right park brake, connections and
cabling.
6
Left park brake fault
Check the left park brake, connections and
cabling.
7
User Interface Fault
Display PCB Fault
Consult a Service Agent
8
Controller Fault
Consult a Service Agent
9
A – Series Bus
Communications Fault
Consult a Service Agent