Generac Portable Products Power Transfer System

15

TROUBLESHOOTING

Problem

Cause

Solution

Generator is running, but no

AC output is available.

1. Generator circuit breaker is

open.

2. Poor connection or defective

cord set.

3. Connected device is bad.

4. Fault in generator.

1. Reset circuit breaker.

2. Check and repair.

3. Select a different appliance or load

that is in good condition.

4. Contact authorized service center.

Generator runs good but

bogs down when loads are

connected.

1. Short circuit in a connected

load.

2. Generator is overloaded.

1. Disconnect shorted electrical load.

2. See “Load Management” on page 14.

All Load Manager™ switches

do not work when on

generator power.

1. Load management switches

in OFF or LINE positions.

2. Generator circuit breaker is

open.

3. Poor connection or defective

cord set.

4. Connected device is bad.

5. Fault in generator.

1. Set Load Manager™ switches in GEN

position.

2. Reset circuit breaker.

3. Check and repair.

4. Select a different appliance or load

that is in good condition.

5. Contact authorized service center.

Appliances don’t work after

utility power comes back on.

1. Load management switch in

OFF or GEN position.

2. Load management switch

circuit breaker(s) is open.

1. Set switch to LINE position.

2. Reset circuit breaker. See “Circuit

Breakers in Load Manager™ Switch”

section, page 14.

Only some loads work on

generator power.

Load management switch circuit

breaker is open.

Reset circuit breaker. See “Circuit

Breakers in Load Manager™ Switch”

section, page 14.

Wattmeter overloaded.

Connected loads on circuits

exceed 3600 watts.

Reduce loads on circuits.