Generac Portable Products Power Transfer System

2

NOTE: The maximum load allowed through each

Load Manager™ switch is 7200 Watts: 30 Amps at

240 Volts or 60 Amps at 120 Volts.

Per National Electric Code, connection of a

generator to any electrical circuit normally

powered by an electric utility must be by means

of approved transfer switch equipment so as to

isolate the electrical circuit from the utility

distribution system when the generator is

operating. Failure to isolate the electrical circuits

by such means may result in injury or death to

utility power workers due to backfeed of

electrical energy.

CAUTION

: Each Load Manager™ switch is for

indoor use only. The connection box is a NEMA

type 3R, intended for outdoor use.

NEMA stands for National Electrical Manufacturer’s Association.

GENERATOR

COMPATIBILITY

Only use a generator that is

factory-equipped with a NEMA

Type 14-50R receptacle.
NEVER use a generator equipped

with a 3-prong 240 Volt receptacle

because damage may occur in

connected appliances.

CARTON CONTENTS

Items in the shipping carton include:
• Two Load Manager™ Switches
• Connecting Box
• Connecting Cord Set
• 50 Amp Connecting Plug
• “Attention” Decal
If any of the above parts are missing or damaged, call

the Generac helpline at 1–800–270–1408.

UNPACKING

Remove the Power Transfer System components from

the shipping carton. Each Load Manager™ switch is

completely prewired and ready for installation. Inspect

the switches and attached wires and flexible conduit

for any shipping damage.
The connection box is supplied ready to be wired.

Inspect the box, the connection cord set, and the

connecting plug for any damage.
The installer will select and attach the connecting cord

plug, as described in the Installation Procedure,

step 22.
Items Not Shipped with Power Transfer System:
The following items, required for system installation,

are not included and must be provided by the installer:
1. Tools required for installation
2. Anchors and screws to mount the power transfer

system components and conduit.

3. Junction box(s), conduit, fittings, wire nuts, and

insulated copper wire for connecting the Load

Manager™ switches to the outside connection box.

SPECIFICATIONS

Model Number.......................................................1403
Maximum Circuits......................................................12
Maximum Load/Circuit from Generator ...........15 Amps
Maximum Load/Circuit from Load Center .......20 Amps
Maximum Watts per Load Manager™...................7200
Connecting Cord Length .........................................8 ft.