LOCATION 162

TIMERS AND COUNTERS (16 segments, numerical data)

Location 162 contains the duration of various system timing functions.

Segment 1

Max Number of network attempts

The number of report attempts the NX-7002 GPRS module makes to send

a report. This can be from 0 to 15.

Segment 2

Report attempts for FTC

The number of attempts that can be made to a specific report destination

before the Fail to Communicate condition is set. This can be from 1 to 15.

Segment 3

Maximum reports in 24 hours

The NX-7002 GPRS module stops reporting messages when the number

of messages in a 24-hour time frame exceeds this number. This can be

from 1 to 255. If set to 0, there is no limitation.

Segment 4

Time in seconds for overall network attempt

The maximum length of time for each attempt by the NX-7002 to report

to each receiver. If the report is not successful during this time, the

attempt is abandoned. This can be from 0 to 255 seconds.

Segment 5

Reserved

Segment 6

TCP/IP Polling time in minutes

This setting must match the TCP/IP polling time set on a TCP/IP receiver.

The setting on the TCP/IP receiver is determined by the speed of the GPRS

network and cost of data transmission. This can be from 1 to 255. If set to

0, the setting is disabled.

Segment 7

Reserved

Segment 8

Reserved

Segment 9

Reserved

Segment 10 Baud rate for CSD/GSM download

This setting must match the baud rate set on the PC modem. 4=2400

Baud, 5=4800 Baud, 6=9600 Baud.

Segment 11 GSM line fault RSSI threshold

The acceptable level of the RSSI signal. If the signal falls below this level

for the amount of time set in segment 12, a line fault is generated. This

can be from 1 to 31. If set to 0, the setting is disabled.

Segment 12 GSM line fault time

The length of time the RSSI signal must be below the RSSI threshold

before a line fault is generated. This can be from 0 to 255 seconds.

Segment 13 Control reporting timeout for secondary reporting

The maximum time during which the control panel must report an event.

If the NX-7002 report control (SMS or TCP/IP report control) is set for

secondary reporting and the control panel does not report the event

during this time, the report control reports the event. This can be from 1

to 255 seconds. If set to 0, the setting is disabled.

Segment 14 Reserved

LOCATION 163

SMS 1 PHONE NUMBER (20 segments)

The phone number to which SMS reports are sent. This phone number is independent from the

phone numbers programmed in the control panel. “14” indicates the end of the phone

number. Program “11” to insert “*” in the phone number, program “12” to insert “#” and

program “13” to insert “+”. It is recommended to add the country prefix before the number. For

example, +32 followed by the phone number.