Ppendix, Eporting fixed codes in, Ontact – GE NetworX NX-7002 User Manual

Page 35

Advertising
background image

A

PPENDIX

1: R

EPORTING FIXED CODES IN

C

ONTACT

-ID

AND

SIA

The table below lists the event codes sent for the following reports (if enabled) when using Contact ID or SIA

formats.

REPORT

CONTACT ID

SIA

MANUAL TEST

601

RX

AUTOTEST 602

RP

OPEN (User Number)

401

OP

CLOSE (User Number)

401

CL

CANCEL (User Number)

406

OC

DOWNLOAD COMPLETE

412

RS

START PROGRAM

627

LB

END PROGRAM

628

LX

RECENT CLOSE (User Number)

401

CR

EXIT ERROR (User Number)

457

EE

EVENT LOG FULL

605

JL

FAIL TO COMMUNICATE

354

RT

EXPANDER TROUBLE (device number)

333

ET

EXPANDER RESTORE (device number)

333

ER

TELEPHONE FAULT

351

LT

TELEPHONE RESTORE

351

LR

SIREN TAMPER

321

YA

SIREN RESTORE

321

YH

AUX POWER OVERCURRENT (device number)

312

YP

AUX POWER RESTORE (device number)

312

YQ

LOW BATTERY (device number)

309

YT

LOW BATTERY RESTORE (device number)

309

YR

AC FAIL (device number)

301

AT

AC RESTORE (device number)

301

AR

BOX TAMPER (device number)

137

TA

BOX TAMPER RESTORE (device number)

137

TR

KEYPAD TAMPER

137

TA

KEYPAD PANIC (audible)

120

PA

KEYPAD PANIC (silent)

121

HA

DURESS

121 HA

KEYPAD AUXILIARY 1

110

FA

KEYPAD AUXILIARY 2

100

MA

RF SENSOR LOST (zone number)

381

*T

RF SENSOR RESTORE (zone number)

381

*R

SENSOR LOW BATTERY (zone number)

384

XT

SENSOR BATTERY RESTORE (zone number)

384

XR

ZONE TROUBLE (zone number)

380

*T

ZONE TROUBLE RESTORE (zone number)

380

*R

ZONE TAMPER (zone number)

137

TA

ZONE TAMPER RESTORE (zone number)

137

TR

ZONE BYPASS (zone number)

570

*B

BYPASS RESTORE (zone number)

570

*U

EARLY OPEN / LATE CLOSE

451

OK

NX-7002 Installation manual

Page 35

09/02/05