Ef g – Generac Power Systems Recreational Vehicle Generator 5413 User Manual

Page 29

Advertising
background image

Section 6

TROUBLESHOOTING FLOWCHARTS

Page 27

REPAIR

OR

REPLACE

REPAIR

OR

REPLACE

TEST 4 – PERFORM

FIXED EXCITATION TEST

/ ROTOR AMP DRAW

Problem 2 –

Generator Produces Zero Voltage or ResidualVoltage (5-12VAC)

(continued)

INSULATION

RESISTANCE

TEST, PAGE 13

TEST ROTOR

INSULATION,

PAGE 14

BAD

BAD

BAD

GOOD

GOOD

E

F

G

TEST 6 – TEST

STATOR DPE

WINDING

TEST 10 –

CHECK ROTOR

ASSEMBLY

TEST 7 – CHECK

SENSING LEADS /

POWER WINDINGS

CHECK VOM FUSES –

VERIFY AMP METER

FUNCTIONS

REPLACE FUSES

– THEN RE-TEST

EITHER OR

BOTH BAD

(PERFORM BOTH TEST 7 & 8)

REPLACE

PRINTED CIRCUIT

BOARD

GO TO PROBLEM 8

TEST 2 – CHECK

STEPPER MOTOR

CONTROL

TEST 12 – CHECK

LOAD VOLTAGE &

FREQUENCY

TEST 13 – CHECK

LOAD WATTS &

AMPERAGE

BAD

GOOD

END TEST

GOOD

Problem 3 – Excessive Voltage/Frequency Droop When Load is Applied

(Underspeed Warning – 4 Flashes on SW1 LED)

NOT OVERLOADED

OVERLOADED

REDUCE LOAD

Advertising