DIAGNOSTIC TESTS

AC POWER WINDING RESISTANCE

*

RV45 (Model 5410/5411)

ACROSS WIRES:

OHMS

11 & 22

0.396

11S & 22S

0.396

33 & 44

0.396

AC POWER WINDING RESISTANCE

*

RV55 (Model 5412/5413)

ACROSS WIRES:

OHMS

11 & 22

0.28

Ω − 0.32Ω

11S & 22S

0.28

Ω − 0.32Ω

33 & 44

0.28

Ω − 0.32Ω

AC POWER WINDING RESISTANCE

*

RV65 (Model 5414/5415)

ACROSS WIRES:

OHMS

11 & 22

0.209

Ω − 0.242Ω

11S & 22S

0.209

Ω − 0.242Ω

33 & 44

0.209

Ω − 0.242Ω

* Resistance values In ohms at 20° C. (68° F.).

Actual readings may vary depending on ambient

temperature. A tolerance of plus or minus 5% is

allowed.

8. Now, set the VOM to its “Rx1 k” or “Rx10,000”

scale and zero the meter.

9. Connect the meter test leads across Stator lead

11 and frame ground. “Infinity” should be read.

10. Connect the meter test leads across Stator lead

33 and frame ground. The reading should be

“Infinity”.

11. Connect the meter test leads across Stator leads

Wire 11 and Wire 33. The reading should be

“Infinity”.

12. Connect the meter test leads across Stator

leads Wire 11 and Wire 2. The reading should be

“Infinity”.

13. Connect the meter test leads across Stator

leads Wire 33 and Wire 2. The reading should be

“Infinity”.

RESULTS:
1. If the Stator passes all steps except Step 7,

repair, re-connect or replace Sensing leads 11S

and 22S.

2. Replace the Stator if it’s power windings fail the

test. (Note Result No. 1).

3. If the Power Windings test good, perform the

“Insulation Resistance Test” on Page 13.

11

33

44

CB2

CB1

BLACk

RED

11S

22S 22

Figure 7-9. – Stator Power Winding Leads

TEST 8 – CHECk BRUSH LEAdS

DISCUSSION:
In Test 4, if application of battery voltage to the Rotor

did NOT result in an output of about one-half rated

voltage, the brush leads could be one possible cause

of the problem. This test will check Wires 4 and 0 for

an open circuit condition.

PROCEDURE:
1. Set a VOM to its “Rx1” scale and zero the meter.
2. Disconnect Wire 4 from the Voltage Regulator and

from the Rotor brush terminal.

3. Connect the VOM test leads across each end of

the wire. The meter should read “Continuity”.

4. Disconnect Wire 0 from the Rotor Brush Terminal.

Connect one meter test lead to Wire 0. Connect

the other test lead to a clean frame ground. The

meter should read “Continuity”.

RESULTS:
1. Repair, reconnect or replace any defective wire(s).
2. If wires check good, go to Test 9.