to Step 2. If the unit does not produce spark or

has weak spark go to Step 4.

2. Do the following:

a. Set a VOM to measure resistance. Connect

the positive (+) meter test lead to Wire 18A

(Wire 18A still removed from the j1 connec-

tor) Connect the negative (-) meter test lead

to a clean frame ground. “Infinity” should be

measured, or 0.5 to 1M ohms, depending

upon the type of VOM used. If “Continuity” is

measured proceed to Step 12.

b. Set a VOM to the diode test range. Attach the

negative (-) meter test lead to Pin Location

j1-14 on the Printed Circuit Board. (Wire 18A

still removed from the j1 connector) Attach

the positive (+) meter test lead to frame

ground. Set the Start-Stop Switch to “START”.

“Infinity” should be measure during crank-

ing and running. If the VOM does not have a

diode test range, set VOM to measure resis-

tance again. “Infinity” should be measured.

3. If Step 1 produced spark and Step 2 tested good,

set the VOM to measure DC voltage. Connect one

test lead to Wire 15 (j1-4) on PCB. Connect the

other test lead to frame ground. Battery voltage

should be measured. Verify that Wire 15 is con-

nected to j1 and that Wire 14 is connected to j1-

5; if reversed the unit will produce no spark.

4. Rotate the flywheel until the magnet is under the

module (armature) laminations (see Figure 7-37).

5. Place a 0.012-0.015 inch thickness gauge

between the flywheel magnet and the module

laminations.

Figure 7-37. – Setting Ignition Magneto

(Armature) Air Gap

6. Loosen the mounting screws and let the magnet

pull the magneto down against the thickness

gauge.

7. Tighten both mounting screws.
8. To remove the thickness gauge, rotate the fly-

wheel.

9. Repeat the above procedure for the second mag-

neto.

10. Repeat Test 55 and check for spark across the

spark tester gap.

11. If air gap was not out of adjustment, test ground

wires.

12. Set the VOM to the diode test position. The meter

will display forward voltage drop across the diode.

If the voltage drop is less than 0.7 volts, the meter

will “Beep” once as well as display the voltage

drop. A continuous tone indicates “Continuity”

(shorted diode). An incomplete circuit (open

diode) will be displayed as “OL.”

13. Disconnect the engine ground harness from the

ignition magnetos and stud connector (see Figure

7-38).

RESULTS:
1. If “Infinity” was not measured in Step 2b, replace

the Printed Circuit Board.

Note: If VOM was set to diode test, a reading of

0.5 volts would be observed when the Start-Stop

Switch is set to “STOP”. If the VOM was set to

resistance, a reading of 0.5 to 1.5M ohms would

be measured. during cranking and running this

reading should go to “Infinity”. Verify that the

meter leads were properly connected as per Step

2 instructions.
2. If battery voltage was not measured in Step 3,

reconnect Wire 15 and Wire 14 to their correct

terminal locations.

A

B

C

ENGINE
GROUND
HARNESS

POSITIVE METER

TEST LEAD

NEGATIVE METER

TEST LEAD

Figure 7-38. – Engine Ground Harness Test Points

Page 56

Section 7
DIAGNOSTIC TESTS

Advertising