Installation, Natural gas (ng) – GSI Outdoors AUTOFLOW 2TF User Manual

Page 33

Advertising
background image

2000 Autoflow

33

Natural Gas (NG)

This dryer is designed to operate

on natural gas. Natural gas units

have a larger orifice to accommo-

date lower pressures sometimes

found with natural gas and do not

have vaporizer coils like liquid

propane units. A regulated pres-

sure of 10 PSI minimum, 30 PSI

maximum must be provided at the

field connection point on the fan

and heater unit, with gas available

in sufficient volume to maintain

the operating pressure.

See the “Fuel Systems and

Recommendations Chart” for

natural gas to determine the cor-

rect size line to run to the dryer.

Have a qualified gas service per-

son inspect the installation to be

sure everything is installed ac-

NG line field connection.

Fuel System Specifications and Recommendations

Natural Gas (NG)

Dryer

Fan Size

36”

36”

42”

42”

42”

42”

Dryer

Horsepower

10-12

15

15

20

30

40

Maximum Heat

Capacity BTU

Per Hour

3.5 million

4.5 million

5.75 million

6.75 million

8.75 million

10.25 million

cording to local codes and ordinances.

After installation is complete check all connections for leaks with

l

iquid detergent or comparable. Wear rubber gloves and eye protection.

DO NOT USE FLAME FOR LEAK TESTING.

Maximum Fuel

Flow Cubic Ft.

Per Hour

3500

4500

5750

6750

8750

10250

Minimum

Line Size

1.1/2”

Orifice

Size

13/32”

1/2”

33/64”

35/64”

19/32”

41/64”

Minimum

Operating

Pressure

1 lb.

1 lb.

1 lb.

1 lb.

1 lb.

1 lb.

Maximum

Operating

Pressure

7 lbs.

7 lbs.

7 lbs.

7 lbs.

7 lbs.

7 lbs.

INSTALLATION