34

ELECTRICAL POWER SUPPLY

Conduit Runs

Control Wires

Run #1

Autoflow Control Box to Master

Fan/Heater Control Box

Five (5)-Control wires 16ga minimum

(NOTE: A shielded two conductor 16ga cable should

be used for the network connections.)

Run #2

Autoflow Control Box to Actuator

Control Box

Five (5)-Control wires 16ga minimum

Run #3

Autoflow Control Box to Wet

Supply Rotary Switch

Four (4)-Control wires 16ga minimum

Run #4

Autoflow Control Box to Storage

Chamber Rotary Switch

Five (5)-Control wires 16ga minimum

Run #5

Autoflow Control Box to Drying

Chamber Rotary Switches

Six (6)-Control wires 16ga minimum

Run #6

Autoflow Control Box to Fill

System Control Box (if applicable)

Ten (10)-Control wires 16ga minimum

Run #7

Master Fan/Heater Control Box to

Slave Fan/Heater Control Box

Four (4)-Control wires 16ga minimum

(NOTE: A shielded two conductor 16ga cable should

be used for the network connections.)

Run #8

Slave Fan/Heater #1 Control Box to

Slave Fan/Heater #2 Control Box

Four (4)-Control wires 16ga minimum

(NOTE: A shielded two conductor 16ga cable should

be used for the network connections.)

Power/Motor Wires

Run #1

Entrance Panel to Master Fan/

Heater Control Box (for fan

motor)

Run #2

Entrance Panel to Slave Fan/

Heater Control Boxes (if

applicable, for fan motor)

Run #3

Entrance Panel to Fill System

Control Box ( if applicable)

-For Fill System #1 motor starter

-For Fill System #2 motor starter

(if applicable)

-For Aeration fan motor starter

Run #4

Fill System Control Box to Fill

System #1 Motor

Run #5

Fill System Control Box to Fill

System #2 Motor ( if applicable)

Run #6

Fill System Control Box to

Aeration Fan Motor

Run #7

Entrance Panel to Actuator

Control Box

-110V AC, 110V N, Ground wire

for battery charger

Grounding

All Control Boxes should be properly

grounded with a ground lug mounted in each control

box.

Advertising