Dryer Fan

Size

Voltage

Horsepower

Copper

100' Run

Aluminium

100' Run

Copper

200' Run

Aluminium

200' Run

Copper

300' Run

Aluminium

300' Run

220v1ph

10-12

6

4

4

2

2

0

208v3ph

10-12

6

4

4

2

3

2

36"

220v3ph

10-12

6

4

4

2

3

2

380v50hz

10-12

10

8

8

6

6

4

460v3ph

10-12

10

8

8

6

6

4

575v3ph

10-12

10

8

8

6

6

4

220v1ph

10-16

4

2

2

0

1

00

208v3ph

15

6

4

4

2

2

0

36"

220v3ph

15

6

4

4

2

3

2

380v50hz

15

6

4

4

2

3

2

460v3ph

15

10

8

8

4

6

3

575v3ph

15

10

8

8

6

6

4

220v1ph

10-16

4

2

2

0

1

00

208v3ph

15

6

4

4

2

2

0

42"

220v3ph

15

6

4

4

2

3

2

380v50hz

15

6

4

4

2

3

2

460v3ph

15

10

8

8

4

6

3

575v3ph

15

10

8

8

6

6

4

208v3ph

20

4

2

4

0

1

00

220v3ph

20

4

2

2

0

1

0

42"

380v50hz

20

6

4

4

2

3

2

460v3ph

20

10

8

6

4

4

2

575v3ph

20

10

8

6

4

4

2

208v3ph

30

1

0

0

000

0000

0000

220v3ph

30

2

0

0

00

00

00

42"

380v50hz

30

6

4

4

2

3

2

460v3ph

30

6

4

4

2

3

2

575v3ph

30

6

4

4

2

3

2

208v3ph

40

1

0

00

000

0000

0000

220v3ph

40

1

0

00

000

0000

0000

42"

380v50hz

40

6

4

4

2

2

0

460v3ph

40

6

4

4

2

2

0

575v3ph

40

6

4

4

2

2

0

Wire Size Information