ELECTRICAL POWER SUPPLY

Autoflow to Actuator Interconnect

The Actuator Control Box houses the 24V
DC linear actuator, two (2) 12V DC Batteries,
and a 24V DC battery charger. The linear
actuator raises and lowers the dump chutes to
unload grain automatically from the drying
chamber to the storage chamber. The two (2)
12V DC batteries act as a backup to prevent wet
grain from dumping into the storage chamber
during a power outage. The 24V DC battery
charger provides a continuous recharge to the
batteries.

To wire the Actuator Control Box to the
Autoflow Control Box do the following.

1)

Run five (5) control wires from the
Autoflow Control Box to the Actuator
Control Box.

2)

Run three (3) power wires from the
Entrance Panel to the Actuator Control
Box.

3)

Connect the wires as shown in figure
20.

Figure 20