Power/motor wiring, Main power schematic – GSI Outdoors AUTOFLOW 2TF User Manual

Page 37

Advertising
background image

2000 Autoflow

37

POWER/MOTOR WIRING

The Following diagram details the configuration

for correct main power installation. Use the diagram

in conjunction with the Electrical Load information and

Wire Size information provided. The diagram details

the correct main power installation for 220V 1 ph, 230V

ph, 460V 3ph, 575V 3ph, and 380V 50hz power

supplies.

On all three phase systems put the leg with the

highest potential difference between that leg and ground

( wild or high voltage leg) on the center terminal (L2)

at the motor starter.

NOTE: Standard electrical safety should be used.

(Refer to the National Electrical Code Standard

Handbook by the National Fire Protection

Association). A qualified electrician should make

all electrical wiring installations. Follow all local

or national electrical safety standards and

ordinances when installing the equipment.

Main Power Schematic