309365

Maintenance

Daily:
Inspect, clean and replace as needed

D

Manifold filter, gun filter and inlet stainer

D

Wet cup for leakage, tighten if needed

D

TSL level

D

Gun trigger safety

D

Tip wear, replace if necessary

D

Electric cord and plug

Weekly:

D

Check tightness of wet cup

D

Inspect all high pressure paint hoses

Annually:

D

Schedule maintenance check at an autho-

rized Graco repair center

Storage

1. Perform Cleanup, page 31

Tip Wear

12

(305)

11

(280)

9

(229)

5,5

(140)

TIP OPENING ENLARGEMENT

New Tip

.015

Worn to

.017

Worn to

.019

Worn to

.021

FLOW RATE in gpm (lpm)

1/4

(0,87)

1/3

(1,14)

3/8

(1,4)

1/2

(1,74)

Note: A 515 tip produces a 10 in. pattern width when measured 12 in. from tip to work

surface; spraying paint with viscosity of 20 sec #4 Zahn cup and at 1600 psi

(110 bar, 11 MPa)

NEW

WORN

OUT

SPRAY PATTERN WIDTH

in inches (millimeters)

Worn Tips Waste Paint

Cost Money!

2. Wrap cord, place siphon tube set in holder