RS-232 / TELNET / UDP COMMANDS

#set_input_name Command
The #set_input_name command provides a name to the selected input. For example,

“Input 1” could be renamed as “Computer 1”. The maximum string length for param2 is

15 characters. Special characters and spaces are not permitted. If required, use the

underscore character (“_”) to separate characters.

Syntax:
#set_input_name param1 param2

Parameters:
param1

Input

[1 ... 16]

param2

Name

Example:
#set_input_name 5 computer1
computer1 is assigned to input 5

#set_ir Command
The #set_ir set the IR channel for the matrix. The associated DIP switch settings for the IR

remote control unit are returned. See page 8 for details on setting the IR channel for the IR

remote control.

Syntax:
#set_ir param1

Parameters:
param1

Channel

[0 ... 3]

Example:
#set_ir 2
RMT_IR - SW1=0,SW2=1