Connection with rs-232c equipment – MITSUBISHI ELECTRIC CP900E User Manual

Page 15

Advertising
background image

15

CONNECTIONS

PRINTING

ADJUSTMENTS

PRECAUTIONS

FEA

TURES

PREP

ARA

TION

OTHERS

TROUBLE-

SHOOTING

RS-232 Connection Cable

Computer (DB9)

Printer (DB25)

Signal

Pin No.

Pin No.

Signal

RXD

2

2

TXD

TXD

3

3

RXD

DR

4

6

DSR

SG

5

7

GND

DR

6

20

DTR

RS

7

5

CTS

CS

8

4

RTS

FG

9

1

FG

#9 on the 9 Pin end of the cable is typically tied to the Shield.

This is just an example. Make sure to check the connection type
for the using equipment.

CONNECTION WITH RS-232C EQUIPMENT

This unit can controlled through a RS-232C port with custom software. (Image data can not be input.)
For the protocol, consult your dealer.

Make sure to turn off the power before setting.

2

2

2

2

2

RS-232C TERMINAL SIGNAL

REMOTE

RS-232C

S-VIDEO IN

S-VIDEO OUT

R

G/G+SYNC

B

Y/SYNC

IN

VIDEO

75

75

/HIGH

AC LINE

OUT

75

/HIGH

75

75

75

75

HIGH

HIGH

HIGH HIGH

ON

OFF

POWER

HIGH

IMPEDANCE

RGB

75

75

/HIGH

HIGH

SYNC

To RS-232C terminal
(RS-232C)

To RS-232C treminal

VCP

Equipment with RS-232C

25

14

13

Pin number

1

Pin No. Signal line name

Description

Directions

1

FG

Protective

---

2

TXD

Transmitted data

Output

3

RXD

Received data

Input

4

RTS

Request to send

Output

5

CTS

Clear to send

Input

6

DSR

Data set ready

Input

7

GND

Signal ground

---

20

DTR

Data terminal ready

Output

RS-232 Connection Cable (Cross-
over cable)
(DB25)

(DB25)

Signal Pin No.

Pin No.

Signal

FG

1

1

FG

TXD

2

2

TXD

RXD

3

3

RXD

RTS

4

4

RTS

CTS

5

5

CTS

DSR

6

6

DSR

DTR

20

20

DTR

GND

7

7

GND

1

1

1

1

1

Connect this unit and RS-232C equipment

with a crossover cable.

2

2

2

2

2

Set the baud rate according to the equipment
to be connected.
Press MENU button, then press STOP button
on remote control unit.

SERVICE MENU is displayed.

3

3

3

3

3

Press

}

}

}

}

}

button to select “RS232C.”

Advertising