External remote terminal 2, Printing (special) – MITSUBISHI ELECTRIC CP900E User Manual

Page 32

Advertising
background image

32

5

2

1

4

3

6 7 8

Pin No.

22k

22k

10k

100

DTC124EK

DC5V

1k

74LVC125

10k

100

DC5V

To VCP

To VCP

From VCP

To VCP

2

6

3

Circuit inside the VCP

5

MEMORY

BUSY2

PRINT

REMOTE

4

BUSY1

74LVC125

10k

100

DC5V

TTL level

TTL level

56k

EXTERNAL REMOTE TERMINAL 2

The image can be stored in memory and printed by sending the remote signal through

the external remote terminal on the rear panel.

Make out the necessary circuit to use this function by referring to the following.

2

2

2

2

2

EXTERNAL REMOTE TERMINAL SIGNAL ALLOCATION (MINI
DIN8PIN)

Pin No.

Function

Description

1

Ground

Earth

2

MEMORY

Memory : When the signal becomes “LOW” from “HIGH”, the

image is stored in memory. (When the signal has

been “LOW” for 15ms or more, the image is stored

in memory. See page 51, 52.)

3

BUSY2

Refer to the BUSY LEVEL setting of REMOTE SET in

SERVICE MENU. See page 52.

4

BUSY1

Refer to the BUSY LEVEL setting of REMOTE SET in

SERVICE MENU. See page 52.

5

PRINT

When the signal becomes “LOW” from “HIGH”, the image is

stored in memory. (When the signal has been “LOW” for 15ms

or more, the image is stored in memory.)

6

REMOTE

The same functions as the supplied remote control can be

controlled.

7

Unused

8

DC3V

Power supply for the remote control DC 1mA Max.

When the signal from BUSY terminal is received with TTL level, keep the following.
| I

OL

| = 2mA or less, | I

OH

| = 1mA or less

| I

OL

| means the current flowing into the unit at Low output, | I

OH

| means the

current flowing out of the unit at High output.

Just after completing printing, there is a period that memory signal is not accepted.

PRINTING (SPECIAL)