CONNECTIONS

PRINTING

ADJUSTMENTS

PRECAUTIONS

FEA

TURES

PREP

ARA

TION

OTHERS

TROUBLE-

SHOOTING

EXTERNAL REMOTE TERMINAL 1

The image can be stored in memory by sending the remote signal through the external
remote terminal on the rear panel. When the MEM&PRN(MEMORY & PRINT) function
is set to ON, the image will be printed after being stored in memory.

Make out the necessary circuit to use this function by referring to the following.

2

2

2

2

2

EXTERNAL REMOTE TERMINAL SIGNAL ALLOCATION (STEREO
JACK)

Pin No.

Function

Description

1

Ground

Earth

2

MEMORY

Memory : When the signal becomes “LOW” from “HIGH”, the

image is stored in memory. (When the signal has
been “LOW” for 15ms or more, the image is stored
in memory. See page 51, 52.)

3

BUSY1

Refer to the BUSY LEVEL setting of REMOTE SET in SERVICE
MENU. See page 52.

When the signal from BUSY terminal is received with TTL level, keep the following.
| I

OL

| = 2mA or less, | I

OH

| = 1mA or less

| I

OL

| means the current flowing into the unit at Low output, | I

OH

| means the

current flowing out of the unit at High output.

Just after completing printing, there is a period that memory signal is not accepted.

1

2

3

1

3

2

Circuit inside and pin No.

Plug pin No.

22k

22k

10k

100

DTC124EK

DC5V

22k

10k

100

DTC124EK

DC5V

22k

To VCP

From VCP

2

3

Circuit inside the VCP

MEMORY

BUSY

DMC2838

Advertising