Remote set remote signal setting display, Adjustments & settings (service menu) – MITSUBISHI ELECTRIC CP900E User Manual

Page 52

Advertising
background image

52

RS232C SET RS-232C signal setting display

This menu does not work when selecting THERMAL : ON or MULTI : OFF(PRN
SELECT).

BAUD RATE

Set the baud rate of RS-232C.

Set the baud according to the connecting device.

COMMAND TYPE

Sets the command type of RS-232C.

Selects the command type of RS-232C to control this unit.

Select “A” for normal setting. Depending on the connected equipment, select “B”

or “C”.

RESPONSE

Selects whether this unit sends RS-232C response to the host

computer or not.

OFF

Does not send response.

ON

Sends normal response.

ERR RES OK

Selects the response code when an error occurs.

NOR

Sends the regular response.

ILL

Sends “job end” even if ILLEGAL error occurs.

INV

Sends “job end” even if INVALID error occurs.

ALL

Sends “job end” when any error occurs.

NO DSR

Sets to use 232C, DSR and DTR.

Sets “NO DSR” according to the connecting device.

OFF

Uses NO DSR.

ON

Does not use NO DSR.

RS232C SET

BAUD RATE

1200/2400/4800/9600

COMMAND

TYPE

A/B/C

RESPONSE

OFF/ON

ERR RES OK

NOR/ILL/INV/ALL

NO

DSR

OFF/ON

REMOTE SET Remote signal setting display

BUSY LEVEL

Selects the level of BUSY signal from the remote terminals 1 and 2

on the rear panel.

LOW

The VCP cannot accept the remote input signal when the signal is

“LOW”.

HIGH

The VCP cannot accept the remote input signal when the signal is
“HIGH”.

The default setting is “HIGH”.

BUSY 1,2 SELECT Selects when the BUSY signal is outputted from the remote terminals

1 and 2 on the rear panel.

PRINTING

Outputs BUSY signal during printing.

MECHA ERR

Outputs BUSY signal when a mechanical error occurs in this unit or

IC chip is not installed. BUSY signal is also outputted when the printing

mechanism is pulled out or the menu is displayed on the monitor.

MEDIA ERR

Outputs BUSY signal when an error for paper or ink sheet occurs.

MEMORY STOP Outputs BUSY signal when MEMORY button is not functioning.

STROBE 1V

After outputting BUSY signal, memory is taken in by waiting to 1 vertical

period.

STROBE 2V

After outputting BUSY signal, memory is taken in by waiting to 2 vertical

periods.

REMAINING

Outputs BUSY signal while the remains of ink sheet becomes the

value set in REMAINING Q’ty.

When either STROBE 1V or STROBE 2V is set to OFF, the other is available for
setting.

REMOTE SET

BUSY LEVEL

LOW/HIGH

BUSY1,2 SELECT

PRINTING

OFF/1/2/1&2

MECHA ERR

OFF/1/2/1&2

MEDIA ERR

OFF/1/2/1&2

MEMORY

STOP

OFF/1/2/1&2

STROBE 1V

OFF/1/2/1&2

STROBE 2V

OFF/1/2/1&2

REMAINING

OFF/1/2/1&2

ADJUSTMENTS & SETTINGS (SERVICE MENU)