RAS96 RASCard User Guide

CommPlete Communications Server

50

2. Enter the E1SETUP command to change the configuration information. At the A:#

prompt type E1setup xy and hit Enter (xy is the CC9600 slot number. For
example, type E1setup 9b to re-provision the E1-1 card.

A:\#e1setup 9b
Use Settings from:

1.

Use Active Settings (pre-configured card)

2.

User System Defaults (new card)

3.

Use Stored Settings (swapping cards)

Enter Selection (q(uit), <1>): 1

Getting E1 Card Info..
1.

Channel Polling Interval (Sec):20

2.

Error Threshold :10

3.

Disconnect Timeout (sec):11

4.

Framing Format : CRC4

5.

Line Coding: Alternate Mark Inversion (AMI)

6.

Signal Options : R2 MF

7.

DNIS-digits(1-64 or 0 for auto) : 0

8.

Country Selection : ITU

9.

Line Buildout : 120 Ohm

Enter Selection (-(previous), q(uit), d(one), <1>): -

A:\#e1setup 9b

Use settings from:

1.

Use Active Settings (pre-configured card)

2.

User System Defaults (new card)

3.

User Stored Settings (swapping cards)

Enter Selection (q(uit), <1>): 2

1.

Channel Polling Interval (Sec) : 20

2.

Error Threshold : 10

3.

Disconnect Timeout (sec) : 11

4.

Framing Format: CRC4

5.

Line Coding: Alternate Mark Inversion (AMI)

6.

Signal Options : R2 Digital

7.

DNIS-digits (1-64 or 0 for auto): 0

8.

Country Selection : ITU

9.

Line Buildout : 120 Ohm

Enter Selection (-(previous), q(uit), d(one), <1>): -