Warning, Caution, Chimney installation – Martin Fireplaces 400BWBIA User Manual

Page 16

Advertising
background image

16

61D0008

Attic Space

See Table 1 for

Roof Opening Size

Firestop Spacer SF

2"min. Clearances

to Combustibles

Model SC Chimney Cap

Storm Collar

(Including with Cap)

Flashing

(612 or 1212)

Max. Installation

Height - 86' Chimney

3' Min. and 2' Above

Any Point

Within 10'

Flue Outlet Height

Third Floor

Area

Second Floor

Area

First Floor

Area

Firestop Spacer SF

Firestop Spacer SF

15" Square Hole
in Joist (2" Air
Space Clearance
To Combustibles)

15" Square Hole
in Joist (2" Air
Space Clearance
To Combustibles)

SC Chimney Cap

Storm Collar

Flashing

(612 or 1212)

13' Min.

Flue Outlet Height

Attic Space

See Table 1 for

Roof Opening

Size

SF Firestop Spacer

(2" Air Space Clearance

to Combustibles)

15" Square

Opening in Joist

2" Min. Clearance

to Combustibles

3' Min. and 2' Above

Any Point

Within 10'

Figure 15 - Residential Installation

Do not install combustible materials
below top spacer. Non-combusitble
materials such as brick or tile may
be used to trim face of fireplace. Do
not cover any part of louvered panel
and cool air inlet. Combustibles must
not overlap the black painted face of
fireplace.

W

ARNING

Do not block air
inlets or air outlets

CAUTION

INSTALLING CHIMNEY SAFETY INFORMATION

(CONTINUED)

CHIMNEY INSTALLATION

Figure 14 - Proper Chimney Height

Minimum Required Roof Opening

Minimum Framed Opening

Roof Pitch “S” Series Double Wall Chimney

0/12

15"x15"

1/12

15"x15

1

/

8

"

2/12

15"x15

1

/

4

"

3/12

15"x15

1

/

2

"

4/12

15"x15

3

/

4

"

5/12

15"x16

1

/

4

"

6/12

15"x16

3

/

4

"

7/12

15"x17

3

/

8

"

8/12

15"x18"

9/12

15"x18

3

/

4

"

10/12

15"x19

1

/

2

"

11/12

15"x20

3

/

8

"

12/12

15"x21

1

/

4

"

Table 1