Gas appliance installation, Caution, Warning – Martin Fireplaces 400BWBIA User Manual

Page 29

Advertising
background image

61D0008

29

GAS APPLIANCE INSTALLATION

2. An approved gas shut off valve must be located outside the fireplace in an area accessible to the users of the fireplace.
3. All gas piping and fitting must be either steel or malleable iron. Unions must be of the ground joint type.
4. Some code authorities prohibit or place restrictions on the use of gas appliances in fireplaces. Check with local code

authorities before proceeding with installation.

5. The gas appliance and all connecting gas piping must only be installed by a licensed gas appliance installer. See Figure

36 for the gas line opening dimensions on the fireplace.

6. The installer of the fireplace and gas appliance must describe the operation of the fireplace and appliance to the people

who will be operating them and leave all instruction manuals with the operator of the appliance.

If an unvented gas appliance is installed in the fireplace, the gas appliance must
only be operated with the fireplace glass door fully open (if included). Only unvented
gas log sets which have been found to comply with the standard for unvented room
heaters, ANSI/IAS/AGA Z21.11.2 are to be installed in this fireplace.

CAUTION

28"max.

Fireplace

Opening

Side Brick

Inner Fireplace Wrap

Outer Fireplace Wrap

Maintain ½"min. Air

Space Clearance to

Combustibles for Gas

Line Out to 4" from

Side of Fireplace

Figure 36 - Gas Line Opening Dimensions

Hearth Brick

Gas Line

Access Tube

Combustive Materials May Be

Located at Zero Clearance to Gas

Line Beyond 4" from Fireplace Side

Do not operate an
unvented gas log set in
this fireplace with the
chimney removed.

W

ARNING