Trim and mantel installation for gas appliances, Warning – Martin Fireplaces 400BWBIA User Manual

Page 31

Advertising
background image

61D0008

31

8

"

47

"

54

"

1

1

/

2

"

max.

12

"

12

"

max.

42

1

/

2

"

TRIM AND MANTEL INSTALLATION FOR GAS APPLIANCES

Mantel Trim Installation (Unvented Gas Appliances Only)
The fireplace face may be left exposed or trimmed. If trim is installed, fasten it securely to face of fireplace. Trim materials

must not extend closer than

3

/

8

" to the vertical edge of fireplace opening if you plan to use glass doors.

1. Install hood on fireplace with mantels 12" from the

opening of fireplace. Mantel may be no more than

12" deep. Combustible framing members may be

placed across top spacers. See Figure 38.

2. Combustible mantel and/or trim may be installed

within shaded area in Figure 39. Use only non-

combustible materials below top of spacers and

behind front face.

Note: These instructions are for acceptable combustible mantel location in GAS APPLIANCES ONLY. See

Figures 40 through 41 for acceptable combustible mantel locations for wood burning fireplaces.

Hood (p/n 075629) must be installed when
mantel is 12" from fireplace opening.
Note: Glass doors must be removed when
using hood.

W

ARNING

Figure 38 - Locating Mantel 12" from Opening

when Using Hood

Figure 39 - Placement of Combustible

Mantel and Trim without Hood

Top Spacers

Note: No

combustible

materials

within 12"

of opening.

2¾" Hood

(p/n 075629)

Non-combustible

Wall Board

Shaded

Area

Advertising