Martin Fireplaces 400BWBIA User Manual

Page 7

Advertising
background image

61D0008

7

Do not install fireplace
over carpeting.

CAUTION

FIREPLACE LOCATION

Plan for the installation of your fireplace. This includes determining

where the unit is to be installed, the vent configuration to be used, framing

and finishing details, and whether any optional accessories (i.e. blower,

wall switch, or remote control) are desired. Consult your local building

code agency to ensure compliance with local codes, including permits

and inspections.
The following factors should be taken into consideration:
• This fireplace should have sufficient access for its safe operation and maintenance.
• Locate a position where the flue system of the fireplace can be properly installed without damaging the integrity

of the building. e.g. cutting wall or ceiling joist (example: load-bearing framing members).

• Install floor protection when the appliance is installed directly on tile or other combustible material.
• Check fireplace and flue system clearance requirements.
• Locate the fireplace in a large and open room that is centrally located in the house. This will optimize heat

circulation and comfort.

• Locate fireplace away from frequently opened doors, central heat outlets or returns, or other places where air

movements may disturb the airflow around the fireplace.

Note: Air turbulence near the fireplace may cause smoke to spill out of the fireplace opening.
• Locate fireplace near a load bearing wall. Make sure the support structure is strong enough or reinforced if

fireplace is to be trimmed with a heavy stone or brick facing and hearth extension.

• This fireplace may be installed along a wall, across a corner, or use an exterior chase. See Figure 2 for suggested locations.
• Location should be out of high traffic areas and away from furniture and draperies.

• Never obstruct the front opening of the fireplace.
• Do

not install in the vicinity where gasoline or other flammable liquids are stored.

• Vent pipe routing. See Venting section found in this manual for allowable venting configurations.
• Minimum clearances to combustibles, side-wall, ceiling, woodwork, and windows must be maintained. See Clearances

Section in this manual.

Figure 2 - Suggested Fireplace Locations