Caution – Martin Fireplaces 400BWBIA User Manual

Page 25

Advertising
background image

61D0008

25

8'max.

OUTSIDE COMBUSTION AIR PRECAUTIONS AND RECOMMENDATIONS

COMBUSTION AIR

1. Locate combustion air assembly at an exterior location which is not likely to be accidentally blocked in any manner.

Locate assembly above the snow line to prevent blockage by snow accumulation.

2. Never mount the combustion air inlet assemblyin a garage or storage area where combustible fumes such as gasoline

might be drawn into the fireplace.

3. Combustion air can be drawn from the crawl space under a house when an adequate supply of air is provided by open

ventilation.

4. Do not take combustion air from attic space or garage space.
5. Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly.

These conditions increase the resistance to the free flow of air through the duct. See Figures 28 through 31 for methods

of installing the outside air for combustion assemblies.

Continued

Figure 28 - Basement Installation

Figure 29 - Concrete Slab Installation

(Optional Outside Air Runs)

Above

Snow

Level

Ground

Level

Plate

Basement
Wall

Termination Cap

Firestop Spacer

Inlet Grill

in Soffit

(Overhang)

Do not take combustion
air from attic space or
garage.

CAUTION