Vermont Castings EWF36A

20005167

installing the Firestop Spacer

in the ceiling hole

A firestop spacer is used to keep pipe spaced properly

and required for safety.
Nail the firestop spacer (at each corner) to the framing

members of the ceiling hole.

NoTE: A firestop spacer

is not required at the roof.
Hole sizes listed in Figure 9 for angled firestop spacers

provide minimum required air space to chimney pipe for

ceiling thickness up to 8” (203 mm). When combined

thickness of ceiling material, ceiling joists and flooring

material exceeds 8” (203 mm), adjustments must be

made in framing to assure that minimum air spaces to

chimney are maintained.

proper Firestop Spacer installation

Figure 18 shows different installation procedures for

both an area that is an attic and an area that is not an

attic.
If the area above the ceiling

is not an attic, position the

firestop spacer with the flange on the ceiling side and

the angled portion extending up into the hole.
If the area above the ceiling

is an attic, position the

firestop spacer with the flange on the top of the framed

hole and the angled portion extending down into the

hole.
Firestop spacers are not available for, nor are they

required on vertical walls.
Do NoT put any sealant around the area where the

outer pipe slides through the firestop spacer. If you seal

this area,

it may cause a fire hazard.

FP593

SR/C

11/20/97

Nails (4)

Attic installation

Joist

Firestop Spacer

Joist

Firestop Spacer

Nails (4)

ceiling installation

FP593

Fig. 18 Firestop spacer installations.

canadian Requirements

for insulation Shield

In Canada, an attic insulation shield is required to

prevent attic insulaiton from contacxting the chimney

section.

NoTE: If the attic insulation shield is used, the

firestop is not required in the attic installation. Framing

dimensions fr the chimney hole should measure 17¹⁄₂” x

17¹⁄₂” (445 x 445 mm). An attic shield MUST be installed

on top of attic joists (above the floor level). (Fig. 19)
NoTE: In the U.S., it is a good idea, although not al-

ways required, to install an attic insulation shield where

blown-in insulation is planned to be used in the atic.

IGF263

MBUF

5/9/96

Attic Insulation

Shield

Nails

(4 Required)

Attic Joist

Ceiling

Base

Flanges

FP263

Fig. 19 Attic shield installation (Canadian requirement).

continue installing pipe to complete Run

Continue attaching pipe sections to complete system

to next level always being careful that the pipe is firmly

snapped locked in place before proceeding to next pipe

section.

chimney Supports

If chimney supports are required, they are installed the

same as elbows. Nail chimney support straps to adja-

cent structural framing, as shown on Figure 16. Bend

straps as necessary and make sure they are secure so

they will support the weight of the chimney. A chimney

support is 2¹⁄₂" (64 mm) long when installed. Consider

this dimension when determining how many straight

chimney sections are needed.
NoTE: Chimney supports are generally used in long

runs in a chase installation.

Additional ceilings

If you encounter additional ceilings, repeat same steps

required for first ceiling installation. See firestop illustra-

tion in Figure 18.

NoTE: If the attic insulation shield is used, the

firestop is not required in the attic installation.