MHP EWF36A User Manual

Page 9

Advertising
background image

9

Vermont Castings EWF36A

20005167

Framing

Framing can be constructed before or after the fireplace

is set in place, however, most installers build the frame

before setting the fireplace.
Frame fireplace with 2 x 4 lumber or heavier materi-

als. Refer to framing dimensions in Figure 1 for basic

fireplace specifications.
NoTE: Framing should be positioned to accommodate

wall covering and fireplace facing material.

Eb1 (Receptacle) hookup

option for circulating Models only
Wiring should be installed by a certified electrician.
Turn off circuit breaker before wiring models.
Once fireplace is secured, complete wiring the fan kit.

Remove knockout in the center of the back of the EB1

and install listed cable clamps. Feed electrical wire

through listed cable clamp leaving approximately six (6)

inches of wire exposed through the EB1. Secure listed

cable clamp to the wire.
Attach white wire from power source to one (1) wire

of receptacle and secure with nut. Attach black wire

from power source to the other wire of receptacle and

secure with nut. Be sure nuts are secured tightly.
Secure EB1 assembly to inside of electrical box cover-

plate using two screws. Attach cover to face of the EB1

while being careful to position excess wire completely

within the EB1, then attach coverplate to fireplace.

chimney Set-Up

Since you have already planned the chimney run, you

should know exactly how the installation is to be ac-

complished - how much pipe is required, the number of

elbows, if any, and type of termination to be used.
cAUTioN: Report to your dealer any parts damaged

in shipment, specifically check the end connection of

chimney sections and elbows.
NoTE: The EWF36A fireplace must use MHSC model

triple wall 8” chimney components only. The installation

procedure described in this manual applies only to this

system.

Straight-Up chimney installation

To mark the centerline of the flue, put the fireplace

in final position and measure out from the wall: 9¹⁄₂"

(241mm). Mark a spot on the ceiling directly above the

fireplace. Draw a line parallel to the back wall through

this mark. (Fig. 8)
Using a plumb bob positioned directly over center point

of fireplace flue collar, mark the ceiling to establish the

chimney center point. (Fig. 8)

offset installation

In order to clear an obstruction, it may be necessary to

offset chimney from vertical. This is accomplished by

using elbows. Use the 30˚ Offset Elbow table on Page 6

to determine proper offset and parts required.
Each offset requires two (2) elbows. The second elbow

is equipped with support straps. It is very important to

install the second elbow in each offset as close to the

ceiling or support as possible so that the elbow straps

can be secured to framing members to help support the

weight of the chimney.
Determine offset distance of your chimney arrangement

from centerline of fireplace to centerline of chimney

where it is to pass through ceiling.
Locate center point of the chimney on ceiling as though

a straight up chimney arrangement is to be used. Mea-

sure your offset dimension from straight up chimney

center point on ceiling.

FPC556a

EPA36

LOCATE CENTER LINE

Circulating model

3/20/02 djt

956O"

(241mm)

Chimney Centerline

Actual Centerpoint

Plumb Line

Plumb Bob

Imaginary Cen-

terpoint

FPC556a

Fig. 8 Locate centerline of chimney with plumb line.