Optional accessories – MHP EWF36A User Manual

Page 29

Advertising
background image

29

Vermont Castings EWF36A

20005167

optional Accessories

Fan kit

Fk26 Fan
The FK26 fan helps distribute heated air from within

the firebox out into the room. The fan is controlled by a

snapstat that turns power on and off as the firebox tem-

perature rises above and falls below a preset tempera-

ture. A rheostat provides for variable fan speeds.
Specifications
115 Volt / 60Hz / .75 Amps
Maintenance
The fan itself does not require regular maintenance,

however, periodic cleaning of the fan and the surround-

ing area is required.
installation
1. Place fan assembly at the back of the unit between

hearth supports. Attach using velcro strips provided.

(Fig. 33)

2. Install thermal sensor (snapstat) on bottom of firebox

by sliding between bracket and firebox.

3. Place electronic fan speed control box (rheostat) to

side bracket. Fasten fan speed control box with #10

- 24 hex nuts.

4. If the EB-1 receptacle box (Pt. #ZA1200) was cor-

rectly connected when the unit was installed, the

fan lead can be directly plugged into the EB-1 plug

socket.

The fireplace, when installed must be

electrically connected and grounded in ac-

cordance with local codes, with the current

cSA c22.1 canadian Electrical code or for

US installations, follow local codes and the

National Electrical code, ANSi/NFpA No. 70.

Any electrical rewiring of this fan must be complet-

ed by a qualified electrician.
Turn off all power before hook up.

FP1323

FK26 fan install

2/27/03 djt

Fan

Heat Sensor

(Snapstat)

Electrical

Box

Fan Speed Switch

(Rheostat)

FP1323

Fig. 33 FK26 fan placement.

Trim kits

A cast face trim kit and a cast louvre kit are available to

enhance the look of your EWF36A fireplace. Installation

instructions are included with the kit.

Model

Description

EWF36ACFTK

Cast Face Trim Kit

EWF36ACLK

Cast Louvre Kit

Screen kit

An optional spark screen, EWF36S, is available to allow

the fireplace to be operated with the doors fully open.
NoTE: When operated with the doors open and the

screen in place, the damper MUST be in the open

position.

Advertising